{"product_id":"mateksys-hall-effect-current-sensor-150a","title":"MATEKSYS Hall Effect Current Sensor - 150A","description":"\u003cdiv data-content-type=\"row\" data-appearance=\"contained\" data-element=\"main\"\u003e\n\u003cdiv data-enable-parallax=\"0\" data-parallax-speed=\"0.5\" data-background-images=\"{}\" data-background-type=\"image\" data-video-loop=\"true\" data-video-play-only-visible=\"true\" data-video-lazy-load=\"true\" data-video-fallback-src=\"\" data-element=\"inner\" data-pb-style=\"DU5QDAA\"\u003e\n\u003cdiv data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\"\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMATEKSYS Hall Effect Current Sensor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 150A sensor with factory calibrated Offset and Sensitivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-content-type=\"row\" data-appearance=\"contained\" data-element=\"main\"\u003e\n\u003cdiv data-enable-parallax=\"0\" data-parallax-speed=\"0.5\" data-background-images=\"{}\" data-background-type=\"image\" data-video-loop=\"true\" data-video-play-only-visible=\"true\" data-video-lazy-load=\"true\" data-video-fallback-src=\"\" data-element=\"inner\" data-pb-style=\"R2QG9UX\"\u003e\n\u003ch2 data-content-type=\"heading\" data-appearance=\"default\" data-element=\"main\"\u003eFeatures\u003c\/h2\u003e\n\u003cdiv data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\"\u003e\n\u003cul\u003e\n\u003cli\u003eNo voltage drop and heat on current sensor components\u003c\/li\u003e\n\u003cli\u003eOffset and Sensitivity are calibrated in factory\u003c\/li\u003e\n\u003cli\u003e0~150A DC Continuous current rating\u003c\/li\u003e\n\u003cli\u003e17ma Power Consumption\u003c\/li\u003e\n\u003cli\u003eHall effect current sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-content-type=\"row\" data-appearance=\"contained\" data-element=\"main\"\u003e\n\u003cdiv data-enable-parallax=\"0\" data-parallax-speed=\"0.5\" data-background-images=\"{}\" data-background-type=\"image\" data-video-loop=\"true\" data-video-play-only-visible=\"true\" data-video-lazy-load=\"true\" data-video-fallback-src=\"\" data-element=\"inner\" data-pb-style=\"W10M2M2\"\u003e\n\u003cdiv data-content-type=\"html\" data-appearance=\"default\" data-element=\"main\" data-decoded=\"true\"\u003e\u003cimg src=\"https:\/\/cdn-v2.getfpv.com\/media\/wysiwyg\/Accessories\/MATEKSYS-Hall-Effect-Current-Sensor---150A-Info.jpg\" alt=\"MATEKSYS Hall Effect Current Sensor - 150A\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-content-type=\"row\" data-appearance=\"contained\" data-element=\"main\"\u003e\n\u003cdiv data-enable-parallax=\"0\" data-parallax-speed=\"0.5\" data-background-images=\"{}\" data-background-type=\"image\" data-video-loop=\"true\" data-video-play-only-visible=\"true\" data-video-lazy-load=\"true\" data-video-fallback-src=\"\" data-element=\"inner\" data-pb-style=\"SH4T3WP\"\u003e\n\u003ch2 data-content-type=\"heading\" data-appearance=\"default\" data-element=\"main\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\"\u003e\n\u003cul\u003e\n\u003cli\u003eVBAT voltage sense: 0~69V, INAV scale = 2100, BF scale = 210, ArduPilot BATT_VOLT_MULT = 21.0\u003c\/li\u003e\n\u003cli\u003eSensitivity: 20mV\/A, INAV\/BF scale = 200, ArduPilot BATT_AMP_PERVLT = 50\u003c\/li\u003e\n\u003cli\u003eVoltage offset error at zero current: +-10mV\u003c\/li\u003e\n\u003cli\u003eContinuous current rating: 0~150A DC\u003c\/li\u003e\n\u003cli\u003eOperating Temperatures: -30~80 °C\u003c\/li\u003e\n\u003cli\u003eCurrent Output Voltage Error: 5%\u003c\/li\u003e\n\u003cli\u003ePower Consumption: 17mA\u003c\/li\u003e\n\u003cli\u003eDimensions: 23x20x23mm\u003c\/li\u003e\n\u003cli\u003eWeight: 7g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\"\u003e\n\u003cp\u003e\u003cstrong\u003eSOLDERING PADS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\"\u003e\n\u003cul\u003e\n\u003cli\u003e5V: power supply for HCS-150A board, support 4~13V IN, 17mA\u003c\/li\u003e\n\u003cli\u003eTX\/RX: for firmware update and configure (to be supported)\u003c\/li\u003e\n\u003cli\u003eVbat: for voltage sense, support 0~69V IN\u003c\/li\u003e\n\u003cli\u003eCurrent: Current signal, 0~3.3V out\u003c\/li\u003e\n\u003cli\u003eVolt: = 1\/21 Vbat, 0~3.3V out\u003c\/li\u003e\n\u003cli\u003eG: GND\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-content-type=\"row\" data-appearance=\"contained\" data-element=\"main\"\u003e\n\u003cdiv data-enable-parallax=\"0\" data-parallax-speed=\"0.5\" data-background-images=\"{}\" data-background-type=\"image\" data-video-loop=\"true\" data-video-play-only-visible=\"true\" data-video-lazy-load=\"true\" data-video-fallback-src=\"\" data-element=\"inner\" data-pb-style=\"KENF3T1\"\u003e\n\u003cdiv data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\"\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cem\u003e\u003cstrong\u003eIMPORTANT NOTES\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\"\u003e\n\u003cul\u003e\n\u003cli id=\"PHHTXSE\"\u003e\u003cspan\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eMount Hall sensor far from iron and magnetic materials.\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-content-type=\"row\" data-appearance=\"contained\" data-element=\"main\"\u003e\n\u003cdiv data-enable-parallax=\"0\" data-parallax-speed=\"0.5\" data-background-images=\"{}\" data-background-type=\"image\" data-video-loop=\"true\" data-video-play-only-visible=\"true\" data-video-lazy-load=\"true\" data-video-fallback-src=\"\" data-element=\"inner\" data-pb-style=\"EFYKIEJ\"\u003e\n\u003ch2 data-content-type=\"heading\" data-appearance=\"default\" data-element=\"main\"\u003eLinks\u003c\/h2\u003e\n\u003cdiv data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\"\u003e\n\u003cul\u003e\n\u003cli\u003eStep File:\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.mateksys.com\/downloads\/other\/HCS-150A_step.zip\" rel=\"noopener\" target=\"_blank\"\u003eHCS-150A_step.zip\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-content-type=\"row\" data-appearance=\"contained\" data-element=\"main\"\u003e\n\u003cdiv data-enable-parallax=\"0\" data-parallax-speed=\"0.5\" data-background-images=\"{}\" data-background-type=\"image\" data-video-loop=\"true\" data-video-play-only-visible=\"true\" data-video-lazy-load=\"true\" data-video-fallback-src=\"\" data-element=\"inner\" data-pb-style=\"QYCBL3U\"\u003e\n\u003ch2 data-content-type=\"heading\" data-appearance=\"default\" data-element=\"main\"\u003eIncludes\u003c\/h2\u003e\n\u003cdiv data-content-type=\"text\" data-appearance=\"default\" data-element=\"main\"\u003e\n\u003cul\u003e\n\u003cli\u003e1x MATEKSYS Hall Effect Current Sensor - 150A \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"MatekSys","offers":[{"title":"Default Title","offer_id":45505993408742,"sku":"19255","price":24.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/9525\/8342\/files\/mateksys_hall_effect_current_sensor_-_150a_3.jpg?v=1734560211","url":"https:\/\/shop.lumenier.com\/products\/mateksys-hall-effect-current-sensor-150a","provider":"Lumenier","version":"1.0","type":"link"}